Solar Collector Water Heater
Tri-element Hitech vacuum tube performance and specification:
| Tube structure |
All-glass double deck co-axial structure | |
|
Glass material |
Borosilicate 3.3 glass | |
|
|
47±0.7mm; Glass thickness 1.6±0.15mm | |
|
58±0.7mm; Glass thickness 1.6±0.15mm | ||
|
70±0.7mm; Glass thickness 2.0±0.15mm | ||
|
|
37±0.7mm; Glass thickness 1.6±0.15mm | |
|
47±0.7mm; Glass thickness 1.6±0.15mm | ||
|
58±0.7mm; Glass thickness 1.6±0.15mm | ||
|
Tube length |
1200mm,1500mm,1600mm,1800mm,1900mm; | |
|
Absorber |
Coating material |
CU/SS-ALN(H)/SS-ALN(L) |
|
Sediment method |
Three Targets magnetron sputtering plating | |
|
Absorptivity |
α: 0.930.96 (AM1.5) | |
|
Emittance |
ε: ≤ 6.0 % (80±5) | |
|
Vacuum degree |
P≤5.0X10-3 (PA) | |
|
Transmittance of glass tube |
T≥0.89 (AM1.5 ISO9806-1:1994) | |
|
Stagnation temperature |
Y: 240260/kW | |
|
Average heat loss |
ULT≤0.60 W/() | |
|
Hail resistance |
25 mm | |
|
Pressure-endure |
0.6 MPa | |
Tri-element Hitech Solar Vacuum Tube: Add a completely closed galss tube into single-target or three-target all glass vcuum tube
Tri-element Hitech All-Glass Solar Vacuum Tube: Add a completely closed galss tube into single-target or three-target all glass vcuum tube. Tri-element Hitech Vacuum Tube will can decrease water when heat exchaneg so that the rise of temperature will be 130% faster.
Specifications of tri-element hitech all-galss solar vacuum tube:
Tube Structure: All-glass duble deck co-axial structure Galss
Material: High borosilicate 3.3 glass
Outer tube diameter and glass thickness:
Φ=47±0.7mm gt=1.6±0.15mm Φ=58±0.7mm gt=1.6±0.15mm Φ=70±0.7mm gt=2.0±0.15mm
Inner tube diameter and glass thickness:
Φ=37±0.7mm gt=1.6±0.15mm Φ=47±0.7mm gt=1.6±0.15mm Φ=58±0.7mm gt=1.6±0.15mm
Tube Length: 800mm 1200mm 1500mm 1600mm 1800mm 1900mm 2000mm 2100mm
Absorption coating property:
Coating Material: CU/SS-ALN(H)/SS-ALN(L)/ALN Emmition Ratio: E∑h=0.04~0.06(80±5)c
Sediment Method: Three target magnetron sputtering plating Absorptivity: As=0.93~0.96(AM1.5)
Vacuum Degree: P≤5.0*10-3Pa) Hail Resistance: Φ25mm
Stagnation temperature (temperature inside of empty evacuated tubes): 260---300c
Average heat loss: ULT 0.4W---0.6W/m2*c Presure endure: 1MPa